Overhaul
Evaporator Housing
- Remove the evaporator housing from the heater and A/C unit. Refer to => [ Heater and A/C Unit Overview ] Heater and A/C Unit Overview.
- Disconnect the connectors from the heater and A/C unit.
1 Screws
• Tightening specification 1.5 Nm
2 Upper Section of Evaporator Housing
3 Screws
• Tightening specification 5 Nm
• Quantity: 2
4 Threaded Plate
• To the threaded connectors for the refrigerant lines on the evaporator
5 Expansion Valve
• Removing and installing, refer to => [ Expansion Valve ] Expansion Valve.
6 Seal / Insulation
• Heat insulation for expansion valve
7 Lower Section Of Evaporator Housing
8 Evaporator
• Check insulation, it must be completely present.
• Removing and installing, refer to => [ Evaporator ] Service and Repair.