Fuel Gauge Sender: Service and Repair
Fuel Level Sensor G
• Observe the safety precautions when working on the fuel supply system. Refer to => [ Safety Precautions ] Fuel Supply.
• Observe the rules for cleanliness. Refer to => [ Clean Working Conditions ] Fuel Supply.
Always follow these instructions before and during work.
Removing
- Remove the fuel delivery unit. Refer to => [ Fuel Delivery Unit ] Fuel Delivery Unit.
- Disengage the wire connectors - 1 and 2 - and disconnect.
- Lift the retaining tabs - 3 and 4 - with a screwdriver and pull the fuel level sensor downward and off - arrow -.
Installing
- Insert the fuel level sensor in the guides on the fuel delivery unit and push upward until it engages.
- Connect the connectors and check for secure locking.
- Install the fuel delivery unit. Refer to => [ Fuel Delivery Unit ] Fuel Delivery Unit.