FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Inspection Procedure 6

INSPECTION PROCEDURE 6: Condenser Fan does not Operate

Radiator Fan and Condenser Fan Drive Circuit
Inspection Procedure 3

TECHNICAL DESCRIPTION
The cause could be a malfunction of the condenser fan motor or of the fan controller.

CIRCUIT OPERATION
- The fan controller is powered from fusible link number 2.
- The ECU [M/T] or PCM [A/T] judges the required revolution speed of radiator fan motor and condenser fan motor using the input signals transmitted from A/C switch, automatic compressor controller, vehicle speed sensor and engine coolant temperature sensor. The ECU [M/T] or PCM [A/T] activates the fan controller to drive the radiator fan motor and condenser fan motor.

TROUBLESHOOTING HINTS
- Malfunction of condenser fan motor
- Malfunction of fan controller

DIAGNOSIS

STEP 1. Check the condenser fan motor.
Q: Is the condenser fan in good condition?
YES: Go to STEP 2.
NO: Replace the condenser fan motor, then go to Step 3.

STEP 2. Check the fan controller.
Q: Is the fan controller in good condition?
YES: Go to STEP 3.
NO: Replace the fan controller, then go to Step 3.

STEP 3. Check the symptoms.
Q: Does the condenser fan operate correctly?
YES: This diagnosis is complete.
NO: Return to Step 1.