P0705
Test 284-287:
Test 288:
SYMPTOM:
P0705-CHECK SHIFTER SIGNAL
When Monitored and Set Condition:
P0705-CHECK SHIFTER SIGNAL
When Monitored: Continuously with the key on.
Set Condition:
POSSIBLE CAUSES
- CHECKING SYMPTOMS AND POSSIBLE CAUSES
- LOW BATTERY VOLTAGE CAUSING SYMPTOM INTERMITTENT CODE P0705
Test 44-50:
Test 51-56:
Test 57-60:
Test 61-64:
Test 65-69:
Test 70-74:
Test 75-79:
Test 80-84:
Test 85-89:
Test 90-94:
Test 85-99:
Test 100-104:
Test 105:
SYMPTOM:
ADDITIONAL CHECK SHIFTER SIGNAL (P0705)
POSSIBLE CAUSES
- PARK/NEUTRAL AND PRNDL SWITCH CONNECTORS DAMAGED
- CUSTOMER COMPLAINT RELATED TO AUTOSTICK OPERATION
- SHIFT LINKAGE OUT OF ADJUSTMENT
- WIRES BETWEEN TCM & TRS SHORT TO VOLTAGE
- WIRES BETWEEN THE TCM AND THE TRS INTERMITTENT
- WIRES BETWEEN THE TCM AND TRS INTERMITTENT SHORT TO GROUND
- ALL PRNDL LIGHTS ILLUM IN PARK OR NEUT OR CODE P0705 RESET
- MANUAL VALVE LEVER EXCESSIVE WEAR
- INTERMITTENT TRS
- T1 SENSE CKT SHORT TO GROUND
- T1 SENSE CKT SHORT TO SIGNAL
- TRS CAUSES PRNDL TO ILLUMINATE WHILE SHIFT TO NEUT
- OPEN TRS T3 SENSE CKT BETWEEN TCM & TRS
- OPEN TRS T41 SENSE CKT BTWN TCM & TRS
- SHORT BETWEEN TRS T3 SENSE CKT & GROUND
- SHORT BETWEEN TRS T3 SENSE CKT AND ALL OTHER CKTS IN CONNECTOR
- TRS T42 SENSE CKT OPEN BETWEEN TCM & TRS CONNECTORS
- SHORT BETWEEN T41 SENSE CIRCUIT & GND
- SHORT BETWEEN TRS T3 SENSE CKT & GROUND
- SHORT BETWEEN TRS T3 SENSE CKT AND ALL OTHER CKTS IN CONNECTOR
- SHORT BETWEEN TRS T41 SENSE CKT & OTHER SIGNAL IN CONNECTOR
- SHORT BETWEEN TRS T42 SENSE CIRCUIT AND GROUND
- TRS DEFECTIVE
- TRS T41 SENSE CIRCUIT SHORT TO GROUND
- TRS T41 SHORT TO OTHER SIGNAL ON TRS CONNECTOR
- TRS T42 SENSE CIRCUIT SHORT TO GND
- TRS T42 SENSE CIRCUIT SHORT TO OTHER SIGNAL
- TRS T42 SENSE CKT SHORT TO SIGNAL IN TRS CONNECTOR
- DEFECTIVE TCM
- PARK/NEUTRAL CKT ON TCM DEFECTIVE
- TRS T1 SENSE ON TCM DEFECTIVE
- TRS T3 SENSE CKT ON TCM DEFECTIVE
- ADDITIONAL CHECK SHIFTER SIGNAL (P0705) Continued
- POSSIBLE CAUSES
- CODE 7 CAUSED BY T41 SENSE CKT ON TCM DEFECTIVE INCORRECT TCM PART NUMBER
- SHIFT LEVER TEST FAILED
- T41 SENSE CKT ON TCM DEFECTIVE
- TRS T1 CKT ON TCM DEFECTIVE
- TRS T3 SENSE CKT ON TCM DEFECTIVE
- TRS T42 SENSE CKT ON TCM DEFECTIVE
- TRS T1 SENSE CIRCUIT OPEN
- TRS T1 SENSE CIRCUIT SHORT TO SIGNAL
- TRS T1 SENSE CIRCUIT SHORTED TO GND