Hydraulic Pump Fluid Reservoir
Hydraulic Pump Fluid Reservoir
Removing
- Remove hydraulic pump. Refer to => [ Hydraulic Pump ] Hydraulic Pump.
• Before removing, place a cloth or a collector tray under the pump to catch any hydraulic fluid that may leak out.
- Open and close the fluid filler plug one time to equalize the pressure.
- Drain the fluid reservoir if necessary.
- Hold the pump and fluid reservoir upright.
- Loosen the hose clamps - 3 - and remove them.
- Remove oil reservoir - 1 - by lightly turning it off of the valve block - 2 -.
• Do not damage the oil screen - 2 - in the valve block - 1 - when doing so.
Installing
• Tightening specifications, refer to => [ Motor Overview and Hydraulic Pump Fluid Reservoir ] Motor Overview and Hydraulic Pump Fluid Reservoir.
Install in reverse order of removal. Note the following:
• Replace the O-ring.
• Secure all of the hose connections with hose clamps using the corresponding methods. Refer to Electronic Parts Catalog (ETKA).
Note location.
• If the fluid reservoir is replaced, make sure the fluid filler plug is exactly vertical and in the center of the valve block.
• Only then are the MIN and MAX marks correct.
- Install the oil reservoir by lightly turning it onto the valve block.
- Install hydraulic pump. Refer to => [ Hydraulic Pump ] Hydraulic Pump.
- Check the fluid level and fill with fluid if necessary. Refer to => [ Hydraulic System, Filling and Bleeding ] Hydraulic System, Filling and Bleeding.