Tower Brace
Tower Brace
Special tools, testers and auxiliary items required
• Pry lever (80 - 200)
Removing
- Remove plenum chamber cover. Refer to => [ Plenum Chamber Cover ] Plenum Chamber Cover.
- Remove the expanding rivet - arrow - using pry lever (80 - 200).
- Remove the nut - 2 - and unclip the cover - 1 -.
- Remove the bolts - arrows - from the plenum chamber bulkhead.
- Remove bolts - 1, 2 and 3 -.
- Remove the tower brace.
Installation
• For the correct tightening specifications, refer to => [ Tower Brace Assembly Overview ] Tower Brace Assembly Overview.
Installation is reverse of removal, but note the following:
- Install the plenum chamber cover. Refer to => [ Plenum Chamber Cover ] Plenum Chamber Cover.