Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Intermittent fault
Check signal cable between combined instrument panel #A13 (breakout box 13) and generator #2 (D+) for an open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check combined instrument panel and generator (GEN) connectors for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information:
- To connect the breakout box, see Connecting breakout box, Combined instrument panel Connecting the Breakout Box.
- For information about signals, see Connector A, #A1 - #A30 , Connector B, #B1 - #B16 , and Connector D, #D1 - #D5.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Intermittent fault
FAULT FOUND - DONE
-------------------------------------------------