FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Current Too High. Permanent Fault






Current too high. Permanent fault

Mechanical check
Carry out the mechanical check according to Mechanical check Mechanical Check.

Was a fault found?

Yes - Verification

No - Checking the values

-------------------------------------------------

Checking the values




- Ignition on
- Connect the Volvo Scan Tool (ST).
Read off the program status of the convertible top. Check the values at the relevant step.

Other information:
- For the comment sheet, see Diagnostic list for convertible tops Diagnostic List For Convertible Tops
- For other values, see Opening and closing the convertible top Opening and Closing the Convertible Top
- To connect the breakout box, see Connecting the convertible control unit breakout box Connecting the Breakout Box.





Are these values correct?

Yes - Checking components and wiring

No - Replacing the potentiometer

-------------------------------------------------

Checking components and wiring








- Check control module connector D. Check for a short-circuit to supply voltage. See Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
- Disconnect the control module.
- Ignition on.
Connect a voltmeter in order between:
D6 and ground, motor, convertible top, right-hand side.
D11 and ground, motor, convertible top, left-hand side.
Check for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Replace the control module if a short-circuit is found.

Other information:
- To connect the breakout box, see Connecting the convertible control unit breakout box Connecting the Breakout Box
- To access or replace the control module see Replacing the control module Service and Repair.









Was a fault found?

Yes - Verification

No - Checking the engine

-------------------------------------------------

Checking the engine




- Check the relevant motor connector for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
- Ignition on.
Connect a voltmeter between the motor connector (red cable) and ground.
Check for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Replace the motor if there is a short-circuit in the motor.
If no fault is found there is probably a short-circuit in the cable between the control module and the motor connectors.
Remedy as necessary.

Other information:
- To access and replace the relevant motor, see Replacing motors Service and Repair.









Was the fault found?

Yes - Verification

No - Fault-tracing information

-------------------------------------------------

Replacing the potentiometer
Replace the potentiometer if the values were not correct. See Replacing the potentiometer Replacing the Potentiometer. Otherwise select "Continue".

Continue - Calibrating the convertible system

-------------------------------------------------

Calibrating the convertible system
It is important that the potentiometer values are calibrated and programmed into the control module if the potentiometer has been replaced. Carry out programming and calibration in VIDA.

Continue - Verification

-------------------------------------------------

Verification




Verification

Hint: After the repair it is necessary to check that the fault has been rectified.








- Ignition off
- Connect the connectors, install the components, etc.
- Ignition on
- Apply parking brake
- Close the luggage compartment lid
- Speed < 4km/h.
Operate the control switch to move the convertible top.
Move the convertible top to its end positions.

Does the convertible top work?

Yes - VERIFIED

No - VERIFICATION FAILED

------------------------

VERIFICATION FAILED - Fault-tracing information

VERIFIED - FAULT FOUND

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - Exit fault-tracing

No - Attempt New Test

------------------------

Attempt New Test - Mechanical check

-------------------------------------------------