Installation
2AR-FE ENGINE CONTROL: AIR FUEL RATIO SENSOR: INSTALLATION
1. INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
(a) Using SST, install the sensor to the exhaust manifold.
SST : 09224-00010
without SST - Torque : 44 Nm (449 kgf-cm, 32 ft-lbf)
with SST - Torque : 40 Nm (408 kgf-cm, 30 ft-lbf)
Text in Illustration
HINT
* Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). When using a torque wrench with a fulcrum length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Service Precautions.
* Make sure SST and the wrench are connected in a straight line.
(b) Connect the sensor connector.
2. INSTALL RADIATOR HOSE CLAMP Installation
3. INSPECT FOR EXHAUST GAS LEAK Installation