CONSULT-III Operation Procedure
CONSULT-III OPERATION PROCEDURECAUTION: If CONSULT-III is used with no connection of CONSULT-III CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which performs CAN communication.
^ Using CONSULT-III, perform a cruise test and record the result. Cruise Test
^ Print the result and ensure that shifts and lock-ups take place as per Shift Schedule.
1. Touch DATA MONITOR on SELECT DIAG MODE screen.
2. Touch MAIN SIGNALS to set recording condition.
3. See Numerical Display, Barchart Display or Line Graph Display.
4. Touch START.
5. When performing cruise test. Refer to CVT-44, "Cruise Test". Cruise Test
6. After finishing cruise test part, touch RECORD.
7. Touch STORE.
8. Touch BACK.
9. Touch DISPLAY.
10. Touch PRINT.
11. Check the monitor data printed out.