HV12 - Check CANP SIG Circuit For Short to Ground
- Key Off.
- Breakout box installed, PCM disconnected.
- Disconnect Scan Tool from Data Link Connector (DLC).
- Measure the resistance between Test Pin 67 (CANP SIG) and Test Pins 91 (SIG RTN) and 24 or 103 (PWR GND) at the breakout box.
- Is each resistance greater than 10,000 ohms?
YES -- CANP SIG possibly shorted to ground in PCM. Go to HV13. HV13 - Check CANP SIG Circuit For Short to VPWR
NO -- SERVICE short to ground in CANP SIG harness circuit. REMOVE breakout box. RECONNECT all components. Complete PCM reset to clear DTCs. Clearing Diagnostic Trouble Codes
Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes