FD7 - Check For Short to Power In PCM
- Key Off.
- Brake switch disconnected.
- Disconnect PCM.
- Key On.
- Are stoplamps still On?
YES -- Go to FD8. FD8 - Check For Short to Power In Shiftlock Actuator
NO -- REPLACE PCM. RECONNECT brake switch. Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes