Charge Air System, Checking For Leaks
Charge Air System, Checking for Leaks
Special tools, testers and auxiliary items required
• Testing Unit for Turbocharger (V.A.G 1687) with Adapter (V.A.G 1687/12)
Procedure
- Remove the engine cover - arrows -.
- Press the release buttons and remove the crankshaft housing ventilation hose - 1 - from the cylinder head cover.
- Free up the vacuum hoses - arrows - on the air guide pipe.
- Loosen clamps - 2 - and - 3 - and remove the air guide pipe.
- Remove bolts - arrows -.
- Loosen hose clamp - 1 - and remove the pulsation damper.
- Install the (V.A.G 1687/12) into the air guide hose - 1 - and secure it with a clamp.
- Connect the (V.A.G 1687) to the adapter.
Prepare the (V.A.G 1687) as follows:
- Remove the pressure regulator valve - 2 - and close valves - 3 - and - 4 -.
• The rotary knob must face upward so the pressure control valve - 2 - can be turned.
- Connect the (V.A.G 1687) to compressed air - 1 - with a commercially available adapter piece.
• If there is water in the viewing glass, drain it through the drain plug - 6 -.
- Open the valve - 3 -.
Damage could result if the pressure is set too high.
• Pressure must not exceed 0.5 bar!
- Set the pressure to 0.5 bar using the pressure control valve - 2 -.
- Open the valve - 4 - and wait until the test circuit is filled. Regulate the pressure to 0.5 bar again if necessary.
- Listen, feel and use commercially available leak detection spray or the ultrasonic tester (V.A.G 1842) to check the charge air system for leaks.
• A small quantity of air dissipates via valves in engine. A pressure retention test is not possible for this reason.
• For information on using the (V.A.G 1842), refer to the => Operating Instructions.
• Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.
Assembling
Assembly is in reverse order of removal, note the following:
• Replace the seal and O-ring.
• The hose connections as well as the air guide pipes and hoses must be free of oil and grease before installing.
• Secure all hose connections with hose clamps appropriate for the model. Refer to the electronic parts catalog ETKA.
• In order to be able to securely mount the air guide hoses on their connectors, spray the screws on the previously used clamps with a rust remover.
- Install the pulsation damper. Refer to => [ Turbocharger Assembly Overview ] Turbocharger Assembly Overview.