Battery Cable to the Starter Motor Control Solenoid.
Operation number: 37213-2
Battery cable to the starter motor control solenoid.
Removal
Note! Removal steps in this procedure may contain installation details.
Perform battery disconnecting and connecting. Battery Disconnecting and Connecting
Remove the following items:
- air cleaner (ACL) housing Refer to: Air cleaner housing, B6304T4 Service and Repair
- the intake manifold Refer to: Induction pipe, B6304T4, TF-80SC AWD Service and Repair
1. Torque: Battery lead to battery lead terminal, 14 Nm
2. Torque: Starter motor B+ terminal, 15 Nm
3. Torque: Generator B+ terminal, 15 Nm
Installation
To install, reverse the removal procedure.