Evaporative Shut Valve: Service and Repair
Replacing the shut-off valve for the carbon filter container
Replacing the shut-off valve for the carbon filter container
Removing the shut-off valve
Remove the carbon filter container according to Replacing the carbon filter container Service and Repair.
Disconnect the connector, clamps and hoses from the EVAP canister shut-off valve.
Remove the EVAP canister shut-off valve.
Installing the shut-off valve
Install the clamps and hoses on the shut-off valve. Check that the hoses are correctly positioned and arenottwisted or kinked.
Connect the connector. Press the quick-release connector together until a clicking sound is heard.