Checking Cables and Connectors
Checking Cables And Connectors
Check the gray 14-pin connector B and the connector on the potentiometer on motor 2 for loose connections according to Checking wiring and terminals - Intermittent faults and contact resistance and oxidation according to Checking wiring and terminals - Intermittent faults.
Check the ground lead between the control module, terminal B:4 (yellow/white cable), and the potentiometer on motor 2 for an intermittent open-circuit according to Checking wiring and terminals - Intermittent faults.
Check the signal and power supply cables between the control module and the potentiometer on motor 2, terminal B:3 and B:5 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals - Intermittent faults.
Checking Wiring and Terminals