Intermittent Fault
Intermittent Fault
For left-hand drive cars:
Check the cable between control module #A18 and the lock unit gray connector #B1 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
For right-hand drive cars:
Check the cable between control module #A18 and the lock unit gray connector #B4 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
Checking Wiring and Terminals - Intermittent Faults
Other information:
- For further information about signals and other values,
- To connect the breakout box, Connecting the Breakout Box, Lock and Alarm (VGLA)