Fluid Pan: Service and Repair
Transmission Fluid Pan
Special tools, testers and auxiliary items required
• Drip Tray for VAS 6100 (VAS 6208)
• Torque Wrench (5-60 Nm) (V.A.G 1783)
Removing
- Remove the noise insulation under the engine.
- Place the drip tray underneath.
- Remove the inspection plug - A -.
- Remove the overflow tube - C - and drain any remaining Automatic Transmission Fluid (ATF).
- Loosen the bolts - arrows - for the transmission pan diagonally.
• Some residual ATF will remain in the pan.
- Remove the pan and gasket.
Installing
Install in he reverse order of removal.
- Clean the two magnets in the pan. Make sure the magnets touch the pan completely.
- Check the gasket for damage and make sure all of the spacers (quantity: 8) are present.
Otherwise, replace the gasket.
- Install the pan and gasket; when doing this be sure not to pinch any wires.
- Make sure the pan gasket fits correctly.
- Tighten the pan bolts - arrows - diagonally and in several steps. Tightening specification, refer to => [ Fastener Tightening Specifications ] Fastener Tightening Specifications.
- Install the overflow tube - C -. Tightening specification, refer to => [ Fastener Tightening Specifications ] Fastener Tightening Specifications.
- Replace the seal - B - for the inspection plug - A -.
- Install the plug - A - and new seal - B - hand tight only.
- Fill the ATF and check the level. Refer to => [ ATF Level, Checking and Filling ] Testing and Inspection.
- Install the noise insulation.