FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Severely Discharged Battery, Charging







Severely Discharged Battery, Charging

Special tools, testers and auxiliary items required

Battery Charger (VAS 5903)


Risk of injury. Observe the warnings and safety precautions => [ Dangers When Working with Batteries ] Dangers When Working with Batteries!


Do not check or charge a battery when the visual indicator has no color or is bright yellow. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

The battery must be replaced.


The polarity protection of the charger clamps is not active in the operation mode "charging severely discharged batteries/Support mode". Connect the charger clamps to the battery terminals correctly according to polarity!

Always set the operating mode that corresponds to the battery. Refer to the Operating Instructions for the (VAS 5903).

The (VAS 5903) does not detect a severely discharged battery, refer to => [ Severely Discharged Batteries ] Severely Discharged Batteries.

Do not touch START/STOP if the charge clamps are connected incorrectly! The (VAS 5903) can be damaged.

The (VAS 5903) will not automatically recognize the battery if the battery voltage is less than 2 volts.

Read the information in the chapter => [ Severely Discharged Batteries ] Severely Discharged Batteries.

The battery temperature must be minimum 10 °C (50° F).

Severely discharged batteries in vehicles must be replaced prior to delivery. Pre-existing damage cannot be ruled out.

Procedure


Switch off the ignition and all electrical consumers.

Remove the key.

- Connect the (VAS 5903). The last selected operation mode is shown on the display, refer to => [ Battery Charger VAS 5903 ] Battery Charger VAS 5903.

- Press the INFO button to select the battery type.






The symbol - 1 - for service charging of wet batteries or the symbol - 2 - for service charging of Gel/Absorbent Glass Mat (AGM) batteries is indicated in the display.

- Set the battery capacity (Ah) on the battery to be charged with the corresponding [Up Arrow] or [Down Arrow] button.

- Attach the red charging clamp (+) to the battery positive terminal.

- Connect the black charging clamp (-) to the negative terminal on the battery/negative connector.

- Press the START/STOP button for approximately 5 seconds. The menu selection "Charging severely discharged batteries/Support mode" is activated.

- Press the [Up Arrow] or [Down Arrow] button to set the battery voltage (6 V/ 12 V /24 V).

If no button is touched within 5 seconds, the (VAS 5903) will return to the main menu (operating mode selection).

- Confirm selected battery voltage with START/STOP button.

Then the inquiry about the correct polarity of the charger clamps is made.

- Verify that the charger clamps are connected to the correct polarity.

- Confirm charging clips are connected to correct poles via START/STOP.

The (VAS 5903) begins charging the severely discharged battery.

End the battery charging process

- Press START/STOP button.

- Remove the charger clamps from the battery terminals.

- Disconnect the (VAS 5903).