FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Battery, Charging







Battery, Charging

Special tools, testers and auxiliary items required

Battery Charger (VAS 5903)


Risk of injury. Observe the warnings and safety precautions => [ Dangers When Working with Batteries ] Dangers When Working with Batteries!


Do not check or charge a battery when the visual indicator has no color or is bright yellow. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

The battery must be replaced.

The battery temperature must be minimum 10 °C (50° F).

Procedure


Switch off the ignition and all electrical consumers.

Remove the key.

- Connect the (VAS 5903). The last selected operation mode is shown on the display. Refer to => [ Battery Charger VAS 5903 ] Battery Charger VAS 5903.

- Press the INFO button to select the battery type.






The symbol - 1 - for standard charge of wet batteries or the symbol - 2 - for standard charge of Gel/Absorbent Glass Mat (AGM) batteries is indicated in the display.

- Set the battery capacity (Ah) on the battery to be charged with the corresponding [Up Arrow] or [Down Arrow] button.

- Attach the red charging clamp (+) to the battery positive terminal.

- Connect the black charging clamp (-) to the negative terminal on the battery/negative connector.

The (VAS 5903) recognizes the nominal voltage of the connected battery (6 V/ 12 V /24 V) and begins the charging process automatically.

The (VAS 5903) begins the final charging when the charge is approximately 80 - 85%. The fourth bar is indicated on the display - 1 -. The battery is ready for operation.






With a charge status of 100%, all bars are indicated on the display - 1 -.






With the battery type standard charge, parallel operation of consumers during the charging process is possible. The charging time is lengthened by this.

Depending on the battery type, the (VAS 5903) switches to maintenance charging after 1 to 7 hours. To reach a 100% charge condition, the battery should remain connected to the (VAS 5903).

Possible malfunctions and how they are handled:

1 - Displayed voltage does not match the nominal voltage

- Hold down the [Up Arrow] or [Down Arrow] button until the charging process begins.

2 - Displayed battery voltage does not match rated voltage - charging process has already begun

- Press the START/STOP button two times.

- Hold down the [Up Arrow] or [Down Arrow] button until the charging process begins again.

3 - The charger does not recognize a battery, when the battery voltage is less than 2 volts

The display remains unchanged.

The selected battery type and Ampere hours (Ah) are displayed.

End the battery charging process

- Press START/STOP button.

- Remove the charger clamps from the battery terminals.

- Disconnect the (VAS 5903).