Leak Detection Pump: Service and Repair
Leak Detection Pump V144
Removing
- Disconnect the vacuum line - 1 -, ventilation line - 2 - and ventilation line - 3 -.
- Remove the nuts - arrows -.
- Remove the leak detection pump with the bracket and disconnect the electrical connector.
Installing
Install in the reverse order of removal. Note the following:
• Before installing the pump with the bracket, connect the electrical connector.
• The vent line - 2 - must engage audibly.
Tightening Specifications
- For the tightening specifications, refer to => [ EVAP System Overview ] EVAP System Overview.