Air Injection Vacuum Control Solenoid Valve: Service and Repair
Secondary Air Injection Solenoid Valve N112
Removing
- Remove the air filter housing. Refer to => [ Air Filter Housing ] Air Filter Housing.
- Remove the battery, the battery tray bolts - arrows - and tray.
- Disconnect the connector - A - and hose - B - from the Secondary Air Injection (AIR) solenoid valve.
- Loosen the coolant pipe; remove the bolts - arrows -.
- Remove the bolts - arrows - and remove the AIR solenoid valve
Installing
Install in the reverse order of removal. Note the following:
- Replace the gaskets.