High Pressure Sensor / Switch: Service and Repair
High Pressure Sensor (G65)
• The high pressure sensor can be removed without discharging the refrigerant circuit.
• There is a check valve installed in the refrigerant line.
If when loosening the high pressure sensor for longer than 1 second coolant is leaking, the high pressure sensor should be secured again and the refrigerant drained. The check valve in the refrigerant lines is defective and must be replaced.
Removing
- Disconnect the connector from the high pressure sensor - 1 -.
- Remove the high pressure sensor - 1 - from the high pressure line (8 Nm).
• Counter-hold the high pressure line/line connections for the high pressure sensor with a suitable tool when loosening and tightening.
Installing
Install in reverse order of removal.
• Always replace the O-ring on the high pressure sensor.