Switch-off Criteria for Activation of Auxiliary Air Heater Heating Element (Z35)
Switch-off Criteria for Activation of Auxiliary Air Heater Heating Element (Z35)
• On vehicles without A/C system, activation is switched off as soon as one of the switch-on requirements is no longer met in Engine Control Module (ECM) or one of the switch-off criteria is detected.
• When one of the switch-on requirements is no longer met.
• The calculate outside air temperature is higher than 11 °C (52° F).
• Generator load is greater than 95%.
• There is no longer a Ground (GND) signal at the ECM from Heater Control Module (J65).