Air Door Actuator / Motor: Service and Repair
Fresh/Recirculating Air Door Motor
Removing
- Remove glove box.
- Disconnect electrical connector - 1 -.
- Remove screw - 3 -.
- Swing motor - 2 - downwards.
- Disconnect motor - 2 - from fresh air/recirculating air door lever.
Installing
Replacement motors are supplied with operating levers in the " recirculating air" position. To ease installation, first do the following:
- Attach electrical connector - 1 - to door motor - 2 -.
- Switch on ignition.
- Operate button for fresh air/recirculating air and observe lever position.
- When the center position is reached, quickly disconnect the electrical connector.
- Insert motor onto the fresh air/recirculating air shaft - 1 -.
• If it is difficult to align and fit the motor to shaft - 1 -, remove Fresh Air Blower (V2), remove Fresh Air Blower (V2) => [ Fresh Air Blower ] Service and Repair and position door/shaft as required.
- Turn motor in direction of - arrow A -.
- Install mounting screw.
- Reconnect electrical connector.