Vacuum Reservoir in Intake Manifold, Checking for Leaks
Vacuum Reservoir in Intake Manifold, Checking for Leaks
Special tools, testers and auxiliary items required
• Hand Vacuum Pump (VAS 6213)
Conditions
Perform a visual inspection to check whether all vacuum hoses to the intake manifold are not damaged and are connected correctly.
Sequence
- Disconnect the vacuum hose - arrow - from the vacuum reservoir in the intake manifold.
- Set the slide ring - 1 - on the (VAS 6213) to position - A - for "vacuum".
- Connect the (VAS 6213) to the intake manifold vacuum reservoir.
- Operate the (VAS 6213) until a vacuum of 0.3 bar has been reached on the pressure gauge.
• Due to the large volume in the vacuum reservoir, up to 30 pumps may be required to generate a vacuum 0.3 bar.
- Observe the pressure for approximately 3 to 5 minutes.
If the vacuum remains at 0.3 bar:
The vacuum reservoir in the intake manifold is OK.
If the vacuum drops.
- Replace the intake manifold.