Separable Stabilizer Bar, Bleeding
Separable Stabilizer Bar, Bleeding
Special tools, testers and auxiliary items required
• Vehicle diagnostic, test and information system (VAS 5051)
• Transparent plastic tube, inner diameter 6 mm, approximately 1 meter in length
- Depressurize hydraulic system using (VAS 5051).
- Check oil level in engine pump assembly. Refer to => [ Separable Stabilizer Bar Hydraulic System, Checking Oil Level and Filling ] Separable Stabilizer Bar Hydraulic System, Checking Oil Level and Filling.
- Connect hose to bleeder nipple - arrows -.
- Secure hose on bleeder nipples using cable ties or hose clamp.
• Without this securing measure, hose would slide from bleeder nipples during bleeding because of high pressure.
- Loosen bleeder nipple by approximately 1 turn.
- Follow instructions on (VAS 5051).
- Tighten bleeder nipple and remove hose.