Rear Blower Regulation
Rear Blower Regulation
Removing
- Bring rear heating and air conditioning unit into service position. Refer to => [ Second Rear Heating and A/C Unit, Service Position ] Second Rear Heating and A/C Unit, Service Position
- Disconnect connector - 1 - at Rear Blower Regulation Motor (Bitron) (V306).
- Lift tab - 2 - slightly and rotate Rear Blower Regulation Motor (Bitron) (V306) in - direction of arrow -.
- Remove the Rear Blower Regulation Motor (Bitron) (V306) from the heating and air conditioning unit
Installing
Install in reverse order.
• Condensation water hose to valve must not be kinked or pinched. Refer to => [ Rear Condensation Water Hose with Valve, Checking ] Rear Condensation Water Hose with Valve, Checking.