Flexible Air Distribution Shaft
Flexible Air Distribution Shaft
Removing
- Remove radio
- Bring flexible shaft into the following position:
- Rotate air distribution rotary switch - 1 - long enough until shaft locking mechanism - 2 - is visible in step-up gearing - 3 -.
- Remove controls for heating and A/C system, Climatic => [ Climatic with A/C Control Module Controls ] Climatic with A/C Control Module Controls
- Carefully pull out adapter for controls.
- Press in retaining tab - arrow - for flexible shaft and remove flexible shaft.
Installing
• When installing flexible shaft, adapter and rotary switch on controls for heating and A/C system, Climatic must have a specific position to each other, otherwise it will malfunction.
Checking
Flexible shaft for adjusting unit of air distribution doors:
- Let fresh air blower run on highest speed. If air flows out of defroster vents in the "Defrost" position and no air flows out of footwell vents, installation of flexible shaft is correct. If this is not the case, remove flexible shaft from adapter. Place controls for heating and A/C system, Climatic onto adapter and rotate rotary knob for air distribution 1 /2 rotation (180°). Then re-connect flexible shaft. Repeat test