Front Exhaust Pipe with Catalytic Converter Assembly Overview
Front Exhaust Pipe with Catalytic Converter Assembly Overview
1 Exhaust Manifold
• Coat the stud bolts with hot bolt paste.
2 Gasket
• Replace
• Note the installed position:
Gasket recess - arrow A - must be located at exhaust manifold recess - arrow B -.
3 Nut
• Replace
• 25 Nm
4 Front Exhaust Pipe with Catalytic Converter
• Protect from shocks and impact stress.
• With a flex joint.
• Flex joint must not be bent more than 10° - otherwise it may be damaged.
• Removing and installing, refer to => [ Front Exhaust Pipe with Catalytic Converter ] Front Exhaust Pipe With Catalytic Converter.
• Install the exhaust system free of stress, refer to => [ Exhaust System, Installing ] Exhaust System, Installing.
5 Clamp
• Before tightening, ensure exhaust system is free of stress, refer to => [ Exhaust System, Installing ] Exhaust System, Installing.
• Installed location, refer to.
• Tighten the bolts evenly.
6 Nut
• 25 Nm
7 Nut
• 23 Nm
8 Front Crossmember
9 Oxygen Sensor (O2S) behind Three Way Catalytic Converter (TWC) (G130)
• 55 Nm
• When reusing an oxygen sensor, only use hot bolt paste to grease the threads. Do not let the paste get onto the slits of the oxygen sensor body.
10 Connector
• Brown, 4 pin.
• Installed location, refer to.
11 Bolt
• 25 Nm
12 Suspended Mount
• Replace if damaged.
Installation Position of Clamp
- Arrow - points in direction of travel.
- Align clamp - 1 - to the marks on the front exhaust pipe - 2 -.
- a - = 5 mm
Bolts must not project beyond the lower edge of the clamp.
Oxygen Sensor Connector Installed Position
Harness connector is located on the right side of the vehicle floor on the bracket.
1. Bracket
2. Harness connector for O2S behind TWC, brown