Leak Detection Pump: Service and Repair
Leak Detection Pump (V144)
Special tools, testers and auxiliary items required
• Torque Wrench (V.A.G 1783)
Removing
- Read the safety precautions before starting. Refer to => [ Safety Precautions ] Fuel Supply.
- Pay attention to the rules of cleanliness. Refer to => [ Clean Working Conditions ] Fuel Supply.
- Remove the right rear wheel.
- Remove the right rear wheel housing liner.
- Disconnect the vacuum line - 1 - from the Leak Detection Pump (LDP).
- Disconnect electrical connector - 2 -.
- Disconnect the connecting line - 3 -.
• Press the securing ring to disengage the line.
- Remove the nuts - arrows -.
- Remove the LDP and bracket.
Installing
Install in reverse order of removal. When doing this note the following:
• Tightening specifications, refer to => [ EVAP System Component Overview ] EVAP System Component Overview.
• The connecting line - 3 - must engage audibly.