Crankshaft, Measuring Axial Play
Crankshaft, Measuring Axial Play
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge (0-10mm) (VAS 6079)
Procedure:
- Install the (VAS 6079) together with the (VW 387) to the cylinder block and set the indicator against the crankshaft counterweight.
- Press the crankshaft by hand against the (VAS 6079) and set the (VAS 6079) to "0".
- Press the crankshaft off the (VAS 6079) and read the value.
Axial clearance:
• New: 0.07 to 0.23 mm.
• Wear limit: 0.30 mm.