FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Lower Oil Pan






Lower Oil Pan

Special tools, testers and auxiliary items required

Used Oil Collecting and Extracting Device (V.A.G 1782)

Hand Drill with Plastic Brush Attachment

Protective Eyewear

Silicone Sealant (D 174 003 A2)

Removing

- Remove the noise insulation.

- Drain the engine oil.

Observe disposal regulations!

- Remove the bolts - 1 through 20 -.






- Remove the oil pan, if necessary loosen by applying light strikes from a rubber mallet.

Installing

Tightening specifications, refer to => [ Oil Pan and Oil Pump Overview ] Oil Pan and Oil Pump Overview.

Note the expiration date of the silicone sealant.

The oil pan must be installed within 5 minutes after application of the silicone sealant.

- Remove the sealant residue from the upper oil pan with a flat scraper.


Risk of eye injury.

Wear protective eyewear.

- Remove any remaining sealant from the lower oil pan using, for example, a rotating plastic brush.






- Clean sealing surfaces, must be free of oil and grease.

- Cut the sealant tube nozzle at the front mark (nozzle diameter: approximately 3 mm).






- Apply the silicone sealant (D 174 003 A2) to clean sealing surfaces of the lower oil pan as shown in the illustration.






The oil pan must be installed within 5 minutes after application of the silicone sealant.

The sealant bead may not be thicker than specified, otherwise excess sealant could enter the oil pan and clog the oil intake pipe.

Thickness of sealant bead: 2 to 3 mm.

- Immediately install the lower oil pan and tighten the bolts - 1 through 20 - in three passes as follows:






1 - Tighten the bolts by hand

2 - Tighten the bolts to 8 Nm

3 - Tighten the bolts an additional 45° (1/8) turn

After installing the oil pan, allow the sealant to dry for approximately 30 minutes. Only after then may the engine oil be added.

- Fill the engine oil, oil capacities, refer to => [ Engine Oil ] Description and Operation.

The rest of the installation is basically a reverse of the removal sequence.