Reading
Measured Value (data) Block, Reading (Function 08)
- Connecting V.A.G 1551 or VAS 5051 and initiating On Board Diagnosis (OBD).
Scan Tool, Connecting
Initiating On Board Diagnosis (OBD)
The measured value block is divided into display group numbers. The assignment of the individual display zones can be taken from the display group overview.
NOTE:
- Display group overview of the Comfort System (vehicles with power windows) 3rd generation.
Evaluating Measured Value Blocks
- Some of the display groups are only relevant for vehicles with the corresponding equipment.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- (08 initiates function "Read measured value block").
Indicated on display:
Rapid data transfer Q
08 Read measured value block
- Confirm entry with -Q- button.
Indicated on display:
Read measured value block HELP
Input display group number XXX
NOTE: The display group number 001 is an example, to illustrate the sequence.
- Press buttons -0-, -0- and -1- for "Display group number 1" and confirm entry with -Q- button.
Indicated on display: (1...4 display zones)
Read measured value block 1 ->
1 2 3 4
NOTE: To change to another display group proceed as follows:
Indicated on display:
Read measured value block HELP
Input display group number XXX
- Now enter the display group number required.