Convenience System, Initiating On Board Diagnostic (OBD)
On Board Diagnosis (OBD) For The Central Locking System, Initiating
Test prerequisites:
- Voltage supply and fuses for the respective system OK.
- To initiate the On Board Diagnosis (OBD) the ignition must be switched on "Terminal 15 on".
NOTE:
- If the display remains blank, check V.A.G 1551 voltage supply referring to Electrical Wiring Diagram.
- Additional operating information can be printed out depending on the program by pressing the HELP button of V.A.G 1551.
- The -> button serves to advance the program sequence.
- The PRINT button is used for switching on the printer (warning lamp in key lights up).
- Connecting scan tool. Scan Tool, Connecting
- Switch on ignition.
- Switch on printer with the Print button (indicator lamp in button lights up).
Indicated on display:
Rapid data transfer HELP
Enter address word XX
Address word for central locking: 35
Indicated on display:
Rapid data transfer HELP
Enter address word XX
- Press buttons -3- and -5-.
Indicated on display after entering address word 35:
Rapid data transfer Q
35 Central locking
- Confirm entry with -Q- button.
and the following is indicated on display:
Indicated on display:
Rapid data transfer
Tester sends address word 35
The scan tool V.A.G 1551 display will show the control unit identification, e.g.:
1C0962258F Central locking 0044 ->
Coding 00256 WSC 06037
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
NOTE:
Rapid data transfer HELP
Control unit does not answer
- If one of the malfunction messages opposite appears in the display, the possible causes of the malfunction can be printed out with the HELP button.
Rapid data transfer HELP
K wire not switching to positive.
- When doing this the ignition must be switched on.
Rapid data transfer ->
No signal from control unit.
- Malfunctions have occurred at the start of or during the program (external interference?).
Rapid data transfer ->
Fault in communication build up
- Check diagnosis wires as well as voltage supply and ground (GND) connection.
- After correcting the possible causes of the fault, once again enter the address word 35 for "Central locking" and confirm with the -Q- button.
Indicated on display after entering the address word 35:
Rapid data transfer
Tester sends address word 35
The scan tool V.A.G 1551 display will show the control unit identification, e.g.:
1C0962258F Central locking 0044 ->
Coding 00256 WSC 06037
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
List of selectable functions
01 - Checking control unit version
02 - Check DTC memory
03 - Output Diagnosis Test Mode (DTM)
05 - Erasing DTC memory
06 - Ending output
07 - Code control unit
08 - Read measured value block
10 - Adaptation
Indicated on display:
Rapid data transfer HELP
Select function XX
NOTE:
- A list of possible functions is printed out after pressing the HELP key.
- Do not select further functions, which can be printed out after pressing the HELP button.
- After the functions have been completed the V.A.G 1551 returns to the mentioned start position.