Removal (from 12/2010)
2GR-FE STARTING: STARTER: REMOVAL
1. DISCONNECT BATTERY NEGATIVE TERMINAL
2. REMOVE AIR CLEANER ASSEMBLY WITH HOSE Removal (from 12/2010)
3. REMOVE AIR CLEANER INLET NO.1 Removal (from 12/2010)
4. REMOVE STARTER ASSEMBLY
(a) Disconnect terminal 50 of the connector from the starter assembly.
(b) Open the terminal cap, remove the nut and disconnect the wire harness from terminal 30.
(c) Remove the 2 bolts and the starter assembly.