Scan Tool Testing and Procedures
MIRROR: POWER MIRROR CONTROL SYSTEM (w/ Memory): DATA LIST / ACTIVE TEST
1. DATA LIST
HINT
Using the Data List displayed on the Techstream, you can read the value of the switch, sensor, actuator, etc. without parts removal. Reading the Data List as the first step of troubleshooting way to shorten the labor time.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Mirror or Main Body / Data List.
(e) Read the Data List according to the display on the Techstream.
Mirror
Main Body
2. ACTIVE TEST
HINT
Performing the Active Test using Techstream allows you to operate the the relay, VSV, actuator, etc. without removal. Performing the Active Test as the first step of troubleshooting is one way to shorten the labor time.
It is possible to display the Data List during the Active Test.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Mirror / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Mirror