FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

DTC 77


DTC 77 Shift Solenoid Valve SLT Circuit






CIRCUIT DESCRIPTION
The throttle pressure that is applied to the primary regulator valve (which modulates line pressure) causes the No.5 solenoid valve, under electronic control, to precisely and minutely modulate and generate line pressure according to the accelerator pedal effort, or engine power output detected. This reduces the fluctuation of line pressure and provides smooth shifting characteristics. Upon receiving the throttle valve opening angle signal, ECM controls the line pressure by sending a predetermined duty ratio to the No.5 solenoid valve located in the valve body, activating the solenoid valve, modulating the line pressure, generating throttle pressure.

WIRING DIAGRAM





INSPECTION PROCEDURE