Blower Motor Removal and Installation
Blower Motor Removal and Installation
Removal
1) Remove passenger side instrument panel undercover. Removal and Replacement
2) Remove screw (1), and then remove passenger side foot duct (2) from HVAC unit.
3) Remove air hose (1).
4) Disconnect connector (2).
5) Remove blower motor (4) by removing screws (3) from HVAC unit.
Installation
Reverse removal procedure noting the following points.
- Make sure protrusion (1) on HVAC unit fits into the installation hole of blower motor (2).