Viscous Coupling: Testing and Inspection
Coupling Assembly Inspection
- Check coupling assembly for oil leakage. Replace it if leakage exists.
- Measure resistance between "1" terminal and "2" terminal of coupling connector (1).
Check harness for open or short if check result is not as specified.
Replace coupling assembly if OK.
Coupling assembly resistance
: 2 - 3 ohms