P0051
DTC P0051 HO2S HEATER CONTROL CIRCUIT LOW (BANK 2 SENSOR 1)1. OUTLINE OF DIAGNOSIS
Detect front oxygen (A/F) sensor heater open or short circuit.
The front oxygen (A/F) sensor heater performs duty control, and the output terminal voltage at ON is 0 V, and the output terminal voltage at OFF is the battery voltage.
Judge as NG when the terminal voltage remains Low.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITION
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
5. DIAGNOSTIC METHOD
Abnormality Judgement
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 4 ms x 250 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgement
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: Less than 1 second