DTC 35
Diagnostic Chart:
Wiring Diagram:
DIAGNOSTIC CHART AND DIAGRAM
1. CHECK ECU VOLTAGE
With ignition "ON," measure voltage between ECU and ground.
Connector & Terminal/Specified value
(B6) No. 14 - ground/10 V, min.
2. CHECK HARNESS CONNECTOR BETWEEN ECU AND MAIN RELAY
1) Turn ignition "OFF".
2) Disconnect ECU and main relay connectors.
3) Measure resistance between ECU connector and relay connector.
Connector & Terminal/Specified value
(B62) No. 14 - (B52) No. 4/0 ohms
3. CHECK POWER SUPPLY TO MAIN RELAY
1) Turn ignition "ON".
2) Disconnect main relay connector.
3) Measure voltage between relay connector and ground.
Connector & Terminal/Specified value
(B52) No. 1 - Ground/10 V, min.
(B52) No. 2 - Ground/10 V, min.
4. CHECK INPUT SIGNAL FROM PURGE CONTROL SOLENOID
1) Turn ignition "ON".
2) Disconnect main ECU connector.
3) Measure voltage between ECU connector and ground.
Connector & Terminal/Specified value
(B62) No. 6 - ground/7 V, min.
Harness:
5. CHECK HARNESS CONNECTOR BETWEEN ECU AND PURGE SOLENOID
1) Turn ignition "OFF".
2) Disconnect ECU and solenoid connectors.
3) Measure resistance between ECU connector and solenoid connector.
Connector & Terminal/Specified value
(B62) No. 6 - (E14) No. 2/0 ohms