Inspection
2ZR-FE ENGINE CONTROL SYSTEM: CAMSHAFT OIL CONTROL VALVE: INSPECTION
1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
(a) Measure the resistance according to the value (s) in the below.
Standard resistance:
If the result is not as specified, replace the oil control valve assembly.
(b) Check the operation.
(1) Connect the positive (+) battery lead to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.
OK:
If the result is not as specified, replace the camshaft timing oil control valve.
NOTICE:
If the valve cannot return properly because of foreign matter intrusion, a small amount of leakage in the advanced direction may occur and a DTC may be output.