Installation
2AR-FE EMISSION CONTROL: PCV VALVE: INSTALLATION
1. INSTALL PCV VALVE
(a) Apply adhesive to 2 or 3 threads of the PCV valve.
Adhesive:
Toyota Genuine Adhesive 1324, Three Bond 1324 or equivalent
(b) Using a 19 mm deep socket wrench, install the PCV valve.
Torque : 27 Nm (275 kgf-cm, 20 ft-lbf)
(c) Connect the No. 2 PCV hose to the PCV valve.
2. INSTALL INTAKE MANIFOLD
Installation