Determining the Cause of the Charge Lamp's Faulty Operation
Determining The Cause Of The Charge Lamp's Fault Operation
- Connect a jumper lead between terminal D+ on the generator and a good grounding point
- The charging Indicator lamp in the main instrument unit should light up.
Is the function correct?
NO - Grounding, Charging Lamp
YES - Continue with Determining The Cause Of The Charge Lamp's Fault Operation
Rectify the generator.
After performing this procedure Final Check - II