Checking the Sensor Preheating Power Supply
Checking The Sensor Preheating Power Supply
Unplug the connector:
- Heated oxygen sensor 2 (592Ra)
- Turn the ignition switch to the ON position.
- Contact Trionic.
- Connect test lamp 86 11 857 to pin 1 of the female connector and a good grounding point.
- Activate:
Fuel Pump Relay (Max 30s.)
On
- The test lamp should light.
Is the function correct?
NO - Rectifying the Lead - I
YES - Checking the Sensor Preheating Control Module Output