Checking the Control Module's Sensor Input
Checking The Control Module's Sensor Input
- Contact Trionic.
Test value: Tank Pressure (Trionic)
The reading should be: 3.1 kPa
Checking the wiring harness
Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness. Observe the multimeter test lamp or diagnostic tool while doing this.
Is the function correct?
NO - Rectifying the Lead - III
YES - Continue with Checking The Control Module's Sensor Input
- Connect a jumper lead between pins 2 and 3 of the male connector
Test value: Tank Pressure (Trionic)
The reading should be: 3.1 kPa
Checking the wiring harness
Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness. Observe the multimeter test lamp or diagnostic tool while doing this.
Is the function correct?
NO - Rectifying the Lead - III
YES - Checking the Wiring Harness