Check Control Module Input With Strapped Circuit Continued
Checking the Control Module Input With A Strapped Circuit (Continued)
- Connect a jumper lead between pins 2 and 3 of the female connector.
Test value: Tonneau latch Switch Left (STC)
The reading should be: OPEN
Checking the wiring harness.
Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness. Observe the multimeter, test lamp or diagnostic tool while doing this.
Is the function correct?
NO - Rectifying the Lead - II
YES - Changing Components