Checking the Relay's Ground Lead For an Open Circuit




Checking The Relay's Ground Lead For An Open Circuit






















Unplug the connector:
- Control module, TWICE (632)







- Connect a jumper lead between pin 4 of the female connector and a good grounding point.







- Turn the ignition switch to START.







- The test lamp should light.

Is the function correct?

NO - Rectifying the Lead - V

YES - Internal Control Module Fault