Vent Control Cable Adjustment
Vent Control Cable Adjustment1. Disconnect the fresh/recirc control cable from the clip and from the door at the blower case (2).
2. Set the fresh/recirc lever to the FRESH position.
3. At the blower case, push the door lever counterclockwise completely rearward, and affix the cable into position.
4. Test the fresh/recirc lever for smooth operation. Verify that the lever stops at the correct positions.